1-SAFETY PHOTOCELL CONNECTION
Insert the brown cable of the safety photocell into the +24 (15.) terminal of the card. Insert the blue cable into the -24 (17th) terminal of the card. Insert the white cable into the com (7.) terminal of the card. Insert the black cable into the photo (9th) terminal. When the red light of the photocell sees the reflector, the yellow and green LED lights of the photocell will turn on.
2-OBJECT REFLECTED PHOTOCELL CONNECTION
Insert the brown cable of the photocell into the +24 (16th) terminal of the card. Insert the blue cable into the -24 (18th) terminal of the card. Insert the black cable into the photo (9th) terminal of the card. Select the letter D for the L and D contact selection on the photocell.
NOTE: If; If the object-reflective photocell is to be connected together with the safety photocell, just remove the white cable of the safety photocell from the com terminal and shunt it with the black cable of the object-reflective photocell and isolate it with tape or terminal.
3-EXTERNAL BUTTON CONNECTION
Number 1 of the cable coming out of the external (double) buttons is connected to the opn (11.) terminal of the control card; Insert cable number 2 into the cls (12.) terminal of the card and the yellow-green cable into the com (7.) terminal of the card. To connect to the external button; Enter the number 1 of the cable in the up button. Enter the number 2 of the cable in the down button. Insert the Yellow-Green cable into the free terminals of the up and down buttons.
4-LIMIT SETTING WITH MECHANICAL SWITCH
In Rayflex mechanical switches, the green cam is the upper limit and the black cam is the lower limit. The yellow cam is also a softening switch. To adjust the upper limit, press the up button of the panel. When the door opens and reaches the desired level above, press the emergency stop button to stop the door. Turn the green cam with a 3 mm hexagon socket so that it presses the microswitch. Then press the down button of the dashboard. When the door reaches the desired level, press the emergency stop button to stop the door. Turn the black cam again with the help of the Allen key and ensure that the microswitch is pressed. Then tighten the fixing screw in the middle of the switch and fix your switches.
NOTE: While setting the mechanical switch, you can change the board’s logic parameter to manual and set your switch limit. After the process is completed, you can switch the board to AUTO (automatic) operating mode from the logic parameter.
5-LIMIT SWITCH SETTING WITH ENCODER
Press the Up and Down buttons on the control card at the same time. Advanced Menu will appear on the screen. You will see four numbers 1. Press the card’s arrow key once, move it one digit to the right, and use the card’s up key and arrow keys to enter the password 1453. Then, go to the 3rd parameter, motor switch settings, with the up button. You can adjust the opening limit by pressing the arrow key twice and using the up button of the card. Make sure that the numbers increase on the right side of the screen when you press the up button. When your door opens and reaches the desired level, press the arrow button on the card. Press the up button once and you will see the shutdown text. Press the arrow button again, press the down button of the card and close the door. Make sure the numbers on the right of the screen are decreasing. When your door reaches the level you want, press the arrow button. Press the ESC key twice to exit the menu. Open and close your door with the up and down buttons on the panel cover. If your door stops at the points you want, your limiting process is finished.
NOTE: When you press the up button of the card while setting the limit, your door should open and their numbers should increase on the right side of the screen. When you press the down button of the card while setting the lower limit, your door should close and the numbers should decrease on the right side of the screen. If your door moves downward when you press the up button of the card while the upper (opening) limit is set, replace any two of the cables entered into the U-V-W terminal, which is the motor terminals. The same process applies to the down button. In other words, if your door moves up when you press the down button, change the position of any 2 of the U-V-W terminals in the same way.
NOTE: If the door moves upwards when you press the up button of the card while setting the limit, but the numbers on the right of the screen do not increase but decrease, you cannot adjust the limit because the encoder direction is not correct. For the solution, change the encoder direction mode of the 3rd parameter 306. 1: Straight and 2: Reverse, choose the correct option and set the limit again from the beginning. Test your door again using the buttons on the cover of the panel.
NOTE: If your door does not stop at the places where you set the upper limit and lower limit when you set your limit and test your door, you need to make a calibration setting. For calibration setting, you can enter the motor limit switch (SW) setting menu, which is the 3rd parameter of the card, and make calibration settings in the 302 Opening Calib Value and 303 Closing Calib Value menus.